BD Insyte Autoguard Winged Shielded IV Catheter features special stabilizing wings that provide a wide surface area for improved catheter securement. The design of Insyte Autoguard Catheters reduces needlestick injuries. The unique push-button shielding mechanism releases the spring and allows the needle and flash chamber to quickly retract into the safety barrel. The process is controlled by physicians as they decide when to do the activation of the push-button shielding mechanism. Insyte Autoguard Winged Shielded IV Catheters are ideal for use in emergency room, operating room and labor and delivery.

Item # Desc Pkg Price
381534 20G x 1.16" (1.1mm x 30mm) Each
$7.65
$5.05
381534 20G x 1.16" (1.1mm x 30mm) 50/Pack
$292.89
$204.99
381534 20G x 1.16" (1.1mm x 30mm) 50/Pack, 4PK/Case
$1142.89
$799.99
381533 20G x 1" (1.1mm x 25mm) Each
$8.59
$5.99
381533 20G x 1" (1.1mm x 25mm) 50/Pack
$318.59
$222.99
381533 20G x 1" (1.1mm x 25mm) 50/Pack, 4PK/Case
$1257.19
$879.99
381523 22G x 1" (0.9mm x 25mm) Each
$11.49
$7.99
381523 22G x 1" (0.9mm x 25mm) 50/Pack
$344.29
$240.99
381523 22G x 1" (0.9mm x 25mm) 50/Pack, 4PK/Case
$1257.19
$879.99
381512 24G x 0.75" (0.7mm x 19mm) Each
$7.19
$4.99
381512 24G x 0.75" (0.7mm x 19mm) 50/Pack
$318.59
$222.99
381512 24G x 0.75" (0.7mm x 19mm) 50/Pack, 4PK/Case
$1257.19
$879.99

Features of Insyte Autoguard Winged Shielded IV Catheters:

BD Insyte Autoguard Shielded IV Catheter detail
  • Insyte Autoguard is designed especially to reduce hit-and-miss attempts by immediately confirming vessel entry so that the user can stay focused to the site of insertion.
  • The Unique design enables the user to see the blood return within the catheter before it reaches the flash chamber.
  • In cases with compromised veins, it is important to get a first stick success. With BD Insyte the healthcare professional can be more confident while accessing the vein.
  • Ultra-smooth micro-surface, exclusive lubrication process, and superior tip integrity enable the easiest insertion possible
  • Easier to place and advance on a wider cross-section of patients
  • Easy to insert
  • Provides longer dwell times with improved patient outcomes
  • Reduces the chance of irritation to the vessel wall, which in turn reduces the incidence of mechanical phlebitis, a major complication of IV therapy
  • Does not contain elasticized PVC or natural rubber latex
  • Can be used for taxol administration
  • BD Vialon biomaterial is a unique, proprietary material developed especially for vascular access. It conforms to the shape of the vessel and is clinically proven to optimize patient outcomes. It offers optimum kink resistance and flexibility for better outcomes

 

How to insert BD Insyte Autoguard Shielded IV Catheter?

How to insert BD Insyte Autoguard Shielded IV Catheter?

Preparation

  • Make sure all items are at hand throughout the procedure
  • Prepare insertion site according to standard policy and procedure
  • Before venipuncture, hold catheter hub and rotate barrel 360 degrees
  • Make sure catheter is seated back in the notch
How to insert BD Insyte Autoguard Shielded IV Catheter?

Venipuncture

  • Approach the vein slowly at a low angle
  • Observe flashback along the catheter (20, 22 and 24 gauge only); in larger gauge sizes, observe flash behind the white button.
How to insert BD Insyte Autoguard Shielded IV Catheter?

Advancement:

  • Upon flashback visualization, lower catheter almost parallel to the skin
  • Before threading, advance entire unit slightly to ensure catheter tip is in the vein
  • Advance catheter into the vein up to the hub, while maintaining skin traction
How to insert BD Insyte Autoguard Shielded IV Catheter?

Needle Removal: 

Before pressing the button

  • Release venous pressure
  • Apply digital pressure beyond the catheter tip
  • Gently stabilize catheter hub
  • Press the white button

Securement:

  • Secure catheter and apply sterile dressing according to standard policy and procedure

 

Precautions before using BD Insyte IV Catheters:

  • Do not withdraw needle from catheter hub before pressing the white button
  • Needle should be retracted prior to disposal in a puncture resistant, leak proof sharps container
  • Never reinsert needle into the catheter as this could shear the catheter
  • Do not use scissors at or near the insertion site

 

Insertion success:

 

  • Release the tip seal before insertion by rotating the barrel 360°
  • Make sure catheter is seated back in the notch
  • Slow down the speed of insertion
  • Lower the initial insertion angle, keeping the elbow low
  • After flash, lower the angle and advance entire catheter/needle unit slightly to ensure the catheter tip is within the vessel

 

Seeing the flash:

 

  • Trust the instinct and take a pause
  • Look for initial flash along the catheter and then in the flash chamber (20, 22, and 24 gauge); in larger gauge sizes observe initial flash behind the white button 
  • Take care of patient factors such as small veins, small patient, low blood pressure, condition of vein, dehydration, etc., that may slow down flash

 

Threading with ease:

 

  • Make sure tip seal is released before insertion by rotating the barrel 360° 
  • After flash, lower the angle and advance entire catheter/needle unit slightly to ensure the catheter tip is within the vessel
  • Push the catheter forward off the needle, while holding the needle stationary
  • Maintain traction on the skin while advancing the catheter

 

Retracting the needle:

 

  • Release the tip seal before insertion by rotating the barrel 360°
  • Place pressure on the vessel beyond the tip of the catheter
  • Make sure needle is not being inadvertently bent while attempting to activate the button

 

Minimizing the blood:

 

  • Release tourniquet before pressing the button
  • Place digital pressure beyond the catheter tip
  • Have IV connector or tubing close by and ready

 

Avoid early activation:

 

  • Be aware of where the fingers are 
  • Remove needle cover in a straight, outward motion

 

Specification

Codes Flow Rate O.D. I.D. Color Code
381512 20 mL/min 0.0260 to .0290 0.0190 to 0.0220 Yellow
381523 35 mL/min 0.0330 to 0.0360 0.0240 to 0.0270 Blue
381533 65 mL/min 0.0410 to 0.0440 0.0300 to 0.0330 Pink
381534 60 mL/min 0.0410 to 0.0440 0.0300 to 0.0330 Pink
381544 105 mL/min 0.0500 to 0.0530 0.0370 to 0.0400 Green
381547 95 mL/min 0.0500 to 0.0530 0.0370 to 0.0400 Green
381554 220 mL/min 0.0670 to 0.0700 0.0520 to 0.0550 Gray
381557 330 mL/min 0.0670 to 0.0700 0.0520 to 0.0550 Gray

Customer Reviews & Questions

No reviews yet
Bought this product? Your review helps other customers choose.
5 questions, 5 answers
  1. Question: Does it reduce hit and miss insertions?

    Asked by John on Mar 6, 2017
    • Answer: Instaflash Needle Technology improves first-stick success and reduces painful hit-and-miss insertions by immediately confirming vessel entry, enabling the user to stay focused on the insertion site.
      Medical Supplies Club Customer Care Store answer
      Helpful?
  2. Question: What is BD Vialon Biomaterial?

    Asked by Tessy on Mar 6, 2017
    • Answer: BD Vialon Biomaterial is a proprietary catheter material that softens up to 70% in the vein, enables longer dwell times, provides greater kink resistance and reduces the chance of mechanical phlebitis by up to 50%.
      Medical Supplies Club Customer Care Store answer
      Helpful?
  3. Question: How to get a successful insertion?

    Asked by Olive on Mar 6, 2017
    • Answer: To get a successful insertion with BD Insyte Autoguard Winged Shielded IV Catheter, follow the below instructions:Make sure the tip seal is released before insertion by rotating the barrel 360 degrees
      Make sure catheter is seated back in the notch
      Slow down the speed of insertion
      Use less force to penetrate the skin
      Lower the initial insertion angle, keeping the elbow low
      After flash, lower the angle and advance slightly
      Medical Supplies Club Customer Care Store answer
      Helpful?
  4. Question: Is there anything to keep in mind while using it?

    Asked by Yuki on Mar 6, 2017
    • Answer: Keep the following things in mind while using BD Insyte Autoguard Winged Shielded IV Catheter:Do not withdraw needle from catheter hub before pressing the white button
      Needle should be retracted prior to disposal into a puncture resistant, leak-proof sharps container per facility protocol
      Never reinsert needle into the catheter as this could shear the catheter
      Do not use scissors at or near the insertion site
      Medical Supplies Club Customer Care Store answer
      Helpful?
  5. Question: Is this or BD IV catheter UNCOATED? Patient is allergic to coatings on iv catheters. Please advise.

    Asked by Kim G. on Dec 2, 2016
    • Answer: BD Insyte Autoguard Winged Shielded IV Catheters patented BD Autoguard push-button shielding technology is proven to effectively safeguard healthcare workers from accidental needle stick injuries.
      Medical Supplies Club Customer Care Store answer
      Helpful?

Write a review

BD Insyte Autoguard Winged Shielded IV Catheters
Overall rating
At least 20 characters0 / 5000
Would you recommend this product?
Shown as first name and last initial
Never shown. Used to match your order.

Please leave out phone numbers, email or street addresses and order numbers. Reviews are checked before they appear.

Ask a question

BD Insyte Autoguard Winged Shielded IV Catheters
Our product team and other customers can answer.0 / 2000
Never shown publicly.

For order or delivery questions, please contact Customer Care. Questions are checked before they appear.

Customer photo
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopwoundcare.com

Close