BD Nexiva Dual Port Closed IV Catheter System

BD Nexiva Dual Port Closed IV Catheter System

Brand/Manufacturer: BECTON DICKINSON
Save UPTO
  • Prescription required
  • FSA Approved

BD Nexiva Dual Port Closed IV Catheter System is the first of its kind all-in-one closed system IV catheter designed to minimize the risk of IV catheter failure. It features proprietary BD Vialon biomaterial that enables longer dwell times. The catheter's built-in stabilization platform minimizes movement that can lead to catheter complications, restarts and associated costs, and reduces dislodgement.

BD Nexiva Closed IV Catheter System Highlights

  • Constructed with BD Vialon Biomaterial
  • Longer dwell times
  • Integrated system
  • Built-In Stabilization Device
  • Quick blood visualization

Item # Desc Pkg Price
383539 18G x 1-1/4" Each
$19.99
$13.99
383539 18G x 1-1/4" 20/Pack
$385.69
$269.99
383539 18G x 1-1/4" 20/Pack, 4/Case
$1499.99
$1049.99
383536 20G x 1" 20/pack
$385.69
$269.99
383536 20G x 1" 20/pack,4pk/Case
$1571.49
$1099.99
383532 22G x 1" 20/pack
$371.49
$259.99
383531 24G x 3/4" 20/pack
$371.49
$259.99

BD Nexiva Closed IV catheter Features

  • BD Q-Syte Luer Access Split Septum
    - A testament to the power of simplicity, its minimal design offers maximum benefits, including high flow rates, exceptional reliability, clear visibility and cleanability.
  • Dual Access
    - A second port allows for simultaneous administration of compatible fluids and medications near the insertion site. A second BD Q'Syte device is included in the package.
  • All-in-One Closed System
    - The pre-assembled system creates a closed single lumen fluid path, designed to contain blood during insertion, reducing potential for blood exposure and the potential for contamination at connection. The system is also capable of withstanding power injections for contrast-enhanced CT scans
  • Built-In Stabilization Device
    - A soft, flexible stabilization platform is integrated into the catheter system. It is designed for stability and comfort to minimize catheter movement in the vessel, as well as irritation to the vessel
  • BD Instaflash Needle Technology
    - Designed to reduce hit-and-miss insertion by confirming the vessel entry, enabling you to stay focused on the insertion site
  • BD Vialon Biomaterial
    - Clinically proven BD Vialon biomaterial has longer indwell times and softens up to 70% in the vessel, reducing the chance of mechanical phlebilitis by up to 50%
  • Meets the CDC Guidelines and Infusion Therapy Standards of Practice for catheter stabilization


BD Nexiva Dual Port Closed IV Catheter System User Manual

BD Nexiva Dual Port Closed IV Catheter System User Guide

BD Nexiva Dual Port Closed IV Catheter System Instruction Manual

BD Nexiva Dual Port Closed IV Catheter System Devices Brochure
 

Direction For Using BD Nexiva Dual Port Closed Catheter

1. Preparation

  • Secure vent plug and BD Q-Syte Luer Access Split Septum
  • Clamp should not be engaged
  • Twist to remove needle cover.
  • Holding as shown, pull back approximately 1/8” on finger grips
  • Push finger grips back to their original position so the stabilization platform and finger grips are snugly together
     
Direction For Using BD Nexiva Dual Port Closed Catheter

2. Insertion And Flashback

  • Hold the system as shown and access the vessel
  • Initial blood return is along the catheter, then up the extension tube
  • Look at catheter for initial blood return
  • Lower and advance the entire catheter and needle unit slightly to ensure the catheter tip is within the vessel
     

     Direction For Using BD Nexiva Dual Port Closed Catheter

3. Advancement
  • Place pad of index finger behind the push-tab and push the catheter off the needle into the vessel
  • Tip: Do not pull back on the needle during advancement
     
     Direction For Using BD Nexiva Dual Port Closed Catheter 
4. Needle Removal
  • Stabilize the catheter system and pull back on the finger grips until the push-tab component releases from the stabilization platform
  • Discard the shielded needle into a puncture-resistant, leak-proof sharps container
  • Tip: Do not hold onto the push-tab component of the device as this will prevent the release of the needle shield
     
     Direction For Using BD Nexiva Dual Port Closed Catheter 
5. Stabilization And Preparation For Use
  • Apply a transparent dressing to cover the septum, allowing maximum use of extension tubing
  • Engage the clamp
  • Remove the vent plug and attach the other BD Q-Syte device
     
     Direction For Using BD Nexiva Dual Port Closed Catheter 
6. Access and Flushing/Infusion
  • Disinfect the BD Q-Syte device with an appropriate antiseptic
  • Insert the male luer of a syringe or administration set using a straight-on approach
  • Release the clamp and flush or start infusion. Secure the extension tubing.
     
     Direction For Using BD Nexiva Dual Port Closed Catheter 
7. Disconnection
  • Clamp before disconnecting to minimize the reflux of blood
  • Hold the BD Q-Syte device during disconnection and use a straight-off approach.
     
     Direction For Using BD Nexiva Dual Port Closed Catheter 

Specification

Product Code Colour Code Gauge Size Catheter Length Catheter O.D (mm) Catheter I.D (mm) Extension Tube I.D (mm) Flow Rate H2O (mL/hr)
383531 Yellow 24 0.75 0.71 0.36 1.22 780
383532 Blue 22 1 0.9 0.52 1.22 1620
383536 Pink 20 1 1.1 0.64 1.65 3240

Customer Reviews & Questions

No reviews yet
Bought this product? Your review helps other customers choose.
2 questions, 2 answers
  1. Question: can you flush the catheter tubing with saline prior to insertion? if not can you give the rational so I may educate my peers?

    Asked by John B. on Sep 17, 2021
    • Answer: Unfortunately, we cannot help you with this question. We recommend that you consult your healthcare provider for diagnosis and advice.
      Medical Supplies Club Customer Care Store answer
      Helpful?
  2. Question: Is it ok to use the BD Q-Syte device (port hub) when using CT power injector with rates of 4.5 ml/s or less?

    Asked by Bill on Mar 5, 2019
    • Answer: We would suggest you to first consult your physician/doctor regarding compatibility of this product with CT power injector.
      Medical Supplies Club Customer Care Store answer
      Helpful?

Write a review

BD Nexiva Dual Port Closed IV Catheter System
Overall rating
At least 20 characters0 / 5000
Would you recommend this product?
Shown as first name and last initial
Never shown. Used to match your order.

Please leave out phone numbers, email or street addresses and order numbers. Reviews are checked before they appear.

Ask a question

BD Nexiva Dual Port Closed IV Catheter System
Our product team and other customers can answer.0 / 2000
Never shown publicly.

For order or delivery questions, please contact Customer Care. Questions are checked before they appear.

Customer photo
Please enter your and your friends email address below.
Fields marked with * are compulsory
 
*
*
*
*


Submit Cancel
The selected product information has been successfully emailed to your friend.

Thank you for using www.shopwoundcare.com

Close